Grounding the console and chassis, Grounding the console and chassis 62 – MTS Model FlexTest SE User Manual
Page 62
![background image](/manuals/568034/62/background.png)
Models FlexTest® IIm/GT/SE Controller Hardware
How To Cable the Analog Chassis to the Hydraulic
Installation
62
How To Cable the Analog Chassis to the Hydraulic Control Panel
Connect J50 DC Pwr on the 497.01 Analog Chassis rear panel to J50 on the
497.05 Hydraulic Control Panel rear panel.
Grounding the Console and Chassis
The system will not function correctly if it is not grounded properly.
The power ground and chassis ground terminals are wired together when the
chassis is manufactured.
Remove the jumper between the two grounds and connect each terminal as
follows:
•
Each chassis ground should be connected to the console with a short ground
cable (PN 037-766-102).
•
Each power ground should be connected at a common location on the power
panel (PN 037-766-1xx).
•
The power panel ground should be connected to the console (PN 037-766-
101).
The system ground cable connects the console to other system components (PN
005-402-3xx).
J50
J1
497.05 Hydraulic Control Panel
497.01 Analog Chassis
PN 046-239-1xx