Service connections, Service connections 149, Chassis service – MTS Model FlexTest SE User Manual
Page 149
![background image](/manuals/568034/149/background.png)
Service Connections
Models FlexTest® IIm/GT/SE Controller Hardware
FlexTest GT Controller Connections
149
Service Connections
The Model 493.10 Chassis can have several service connectors. There are two
types of connectors:
•
The chassis connection monitors the power supply.
•
The connection on the I/O Carrier module monitors the output of each
mezzanine card.
Chassis service
The J39 Power Monitor connector is located on the rear panel of the chassis. It
functions as test points for a service technician. It allows you to check all of the
power supply voltages along with the status of the overtemperature sensor and
the power fail circuit.
2
3
4
5
6
7
8
9
11
14
+12 Volts
-12 Volts
+15 Volts
-15 Volts
+24 Volts
2.5 Volts Reference
Temperature
+5 Volts
Ground
Ground