Analog I/O Connections
Models FlexTest® IIm/GT/SE Controller Hardware
FlexTest GT Controller Connections
115
Analog inputs
The analog-to-digital mezzanine cards accommodate up to six analog input
signals. Each A/D input signal must be within ±10 volts.
•
Use pin 3 or 6 to prevent problems with floating grounds between devices.
•
Analog inputs can be connected at the BNC connectors of a Model 493.75
Analog In transition module and the outputs from this module are connected
to the Model 493.40 I/O Carrier module.
•
Analog inputs can be connected at the BNC connectors of a Model 493.77
Filtered Analog Input transition module and the outputs from this module
are connected to the Model 493.40 I/O Carrier module.
+
-
+
-
+
-
Input 1
Analog
Ground
Input 2
Analog
Ground
Input 3
Input 4
Input 5
Input 6
+
-
+
-
+
-
+
-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
J4 - J7
To
A/D
From
A/D