Analog i/o connections, Analog i/o connections 114 – MTS Model FlexTest SE User Manual
Page 114
![background image](/manuals/568034/114/background.png)
Models FlexTest® IIm/GT/SE Controller Hardware
Analog I/O Connections
FlexTest GT Controller Connections
114
Analog I/O Connections
The Model 493.45 A/D and Model 493.46 D/A mezzanine cards are installed in
the Model 493.40 I/O Carrier front panel module. A connection from the front
panel mezzanine card to a rear panel BNC transition module allows easy access
to the analog channels.
Note
The external analog source can be a stand-alone function generator,
another controller, or a computer controlled analog output.
493.76
Analog Out
493.75
Analog In
493.40
I/O Carrier
External Analog Source
Front
Rear
493.10 Chassis
Analog Monitor
Front/Rear Cable Conduit
FS
0
t
FS
0
t
0
t
Select Waveform
Generator
410.81
Function
Control Mode
Output Mode
Output
Remote Local
Local
Single
Cycle
Local
Start
Finish
Cycle
& Stop
Ret to
Zero
Trigger
Manual
Bkpt
Hold
Main
Sync
Output to 0
+100% FS
+100% FS
Breakpt
5 - 05%
Full Scale
Hold Time (sec)
Frequency (Hz)
Ramp Time 1 (sec)
Ramp Time 2 (sec)
FS
0
Normal
Invert