J49 auxiliary power, Cj51 box in, J49 auxiliary power 234 cj51 box in 234 – MTS Model FlexTest SE User Manual
Page 234: J49 auxiliary power 234, Cj51 box in 234, Jumper plug required
![background image](/manuals/568034/234/background.png)
Models FlexTest® IIm/GT/SE Controller Hardware
J49 Auxiliary Power
FlexTest SE Controller Connections
234
Jumper plug required
If connector J43 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug PN 100-057-245, or jumper pins: 1-2,
3-4.
J49 Auxiliary Power
See
CJ51 Box In
Connector J51 Box In allows the Model 493.02 chassis to receive clock,
hydraulic, and interlock signals from another Model 493.02 chassis.
J51 Connector Pin Assignments
P
IN
N
AME
F
UNCTION
1
+clk in
+External clock input
2
hyd high in
Hydraulic high input
3
reset in
Interlock reset request input
4
signal return
Signal return for optically isolated inputs
5
/intlk in
Hydraulic interlock input
6
hyd low in
Hydraulic low input
7
signal return
Signal return for optically isolated inputs
8
master/slave in
Master -/Slave select input
9
- clk in
- External clock input
10
hyd hi return out
Hydraulic high return output
11
reset return out
Interlock reset return output
12
ground
Signal ground
13
/intlk return out
Hydraulic interlock return output
14
hyd low return out
Hydraulic low return output
15
ground
Signal ground