Analog inputs – MTS Model FlexTest SE User Manual
Page 126
Models FlexTest® IIm/GT/SE Controller Hardware
ADDA II Connections
FlexTest GT Controller Connections
126
Analog inputs
The analog-to-digital mezzanine cards accommodate up to eight analog input
signals. Each A/D input signal must be within ±10 volts.
•
Analog inputs can be connected at the BNC connectors of a Model 493.81
Analog In transition module and the outputs from this module are connected
to the Model 493.50 ADDA II module.
•
Analog inputs can be connected at the BNC connectors of a Model 493.83
Filtered Analog Input transition module and the outputs from this module
are connected to the Model 493.50 ADDA II module.
Input 1
Input 2
Input 3
Input 4
J 1 1 , J 1 3
J 1 5 , J 1 7
J 1 2 , J 1 4
J 1 6 , J 1 8
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
Input 5
Input 6
Input 7
Input 8
To
A/D
From
493.81 Analog In
Module
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8