Remote station controller connection, Remote station controller connection 147 – MTS Model FlexTest SE User Manual
Page 147
![background image](/manuals/568034/147/background.png)
Remote Station Controller Connection
Models FlexTest® IIm/GT/SE Controller Hardware
FlexTest GT Controller Connections
147
Remote Station Controller Connection
The optional Remote Station Controller (RSC) module requires a Model 498.71B
GRES III VMEbus module and a Model 493.71 Serial Interface transition
module to be installed in the chassis. The RSC can be connected to any of the
four J50 connectors of the serial interface. An interlock is permanently assigned
to each J50 connector (e.g., J50A= Interlock 1). Connecting an RSC
automatically assigns the RSC pod to the interlock.
The .hwi file defines which connector is used for each station. For more
information, see
The RSC control panel is available in two configurations; one provides an E-Stop
and HPS control for single station configurations, and the other provides a
Station Stop with no HPS control for multi-station configurations.
J50D
J7 SERIAL
J50C
J50B
J50A
m
493.71
Serial
Interface
Hold
Stop
Run
Off
Low
High
HPS
Off
Low
Interlock
HSM
Test
Manual Control
F1
F2
F3
F4
Status
Remote Station Control
Enable /
Disable
Reset
High
Emergency Stop
CLOCK OUT
EVENT OUT
J3 IN
J6 STATION
J7 SERIAL
EVENT IN
J4 OUT
J5 DEBUG
+12V
m
498.71B
GRES III
055-634-2xx (E-Stop)
or 055-634-3xx (Station Stop)
049-876-501
Use Jumper Plug 055-634-101
in these connectors.