Sensor connections, Sensor connections 88 – MTS Model FlexTest SE User Manual
Page 88
Models FlexTest® IIm/GT/SE Controller Hardware
Sensor Connections
FlexTest GT Controller Connections
88
Sensor Connections
Sensor connections require a conditioner mezzanine card be installed in the I/O
Carrier module. The following conditioners can be installed:
Note
Model 493.21B Digital Universal Conditioners are not compatible with
stand-alone FlexTest SE Controllers.
•
Model 493.21B Digital Universal Conditioner
•
Model 493.21BC Digital Universal Conditioner
•
Model 493.25 Digital Universal Conditioner
•
Model 493.47 Encoder
•
Model 493.48 Acceleration Conditioner
Each Carrier module can include up to four mezzanine cards. Each installed
mezzanine card is assigned a specific I/O Carrier module front panel connector
(J4–J7 I/O). These connections can be used for any type of sensor (provided the
appropriate mezzanine card is installed).
A hardware interface file (.hwi) defines each type of module (and their associated
mezzanine cards) and maps each module location for the system software. The
.hwi file and the physical locations for each type of module and associated
mezzanine cards must match.