Models FlexTest® IIm/GT/SE Controller Hardware
Hydraulic Configurations
245
Compatible Controllers
You can mix Models 493.07, 458, 490, and 497.05 Controllers directly on the
same HPU (without the use of an HPU isolation box).
You cannot mix Models 493.07, 458, 490, and/or 497.05 Controllers with 436,
413.05, or 413.8X Controllers unless you use an isolation box.
You can jumper the Model 493.07 Converter box so you can use it directly with
436 and 413.05 Controllers. However, if you do this you must use an isolation
box if you attempt to use the Converter Box with Models 458, 490, and 497.05
Controllers. See Appendix B,
* For standard Model 493.07 Converter Box jumper setting only. Alternate settings are required for Model
436.11 and 413.05 controllers. See Appendix B: Model 493.07 Converter Box.
J25
HPS
HPU
J25
HPS
039-708-7XX (24 V DC)
039-708-8XX (115 V AC)
J1
HPS
458* or
490.01*
497.05*
High-level Y cable
005-407-801 (24 V DC)
005-401-801 (115 V AC)
039-713-8XX (24 V DC)
039-714-6XX (115 V AC)
039-710-7XX (24 V DC)
039-710-8XX (115 V AC)
493.10
Chassis
493.07