2 setting ip addresses, Setting ip addresses – Lenze PC-based Automation Industrial PC User Manual
Page 45
2.5 EN - 01/2012
L
45
Industrial PC | Parameter setting & configuration
Web-based parameterisation with »WebConfig«
Requirements for working with the web-based parameterisation
The parameter lists can be found in the chapter entitled:
7.2
Requirements for working with the web-based parameterisation
This chapter provides you with information on how to prepare a remote connection for the
web-based parameterisation.
7.2.1
Online connection between the Engineering PC and Industrial PC
Connect the Engineering PC directly to the Industrial PC using a network cable.
or
Connect the Industrial PC to the network to which the Engineering PC has access.
7.2.2
Setting IP addresses
Setting for the direct connection between the Engineering PC and Industrial PC:
How to set the static IP address of the Engineering PC:
1. Open the Network connections dialog box Network connections.
(StartSettingsNetwork connections)
2. Select the network interface the Industrial PC is connected to.
Right-click Properties.
3. Select Internet protocol (TCP/IP).
4. Click the Properties button.
5. Select the Alternative configuration tab.
Note!
In the case of a direct connection between the Engineering PC and the Industrial
PC, a crossed network cable is required.
The settings of the static IP address of the Engineering PC are only to be carried
out for the direct connection between the Engineering PC and Industrial PC.
Note!
Recommended setting for the Engineering PC:
IP address: <192.168.5.100>
Default setting of the Industrial PC:
IP address: <192.168.5.99>, subnetwork <255.255.255.0>.