Industrial PC | Parameter setting & configuration

Parameter reference

Parameters of standard devices

152

L

2.5 EN - 01/2012

C0214

C0216

C0217

2500 2500
2750 2750
3000 3000
3250 3250
3500 3500
3750 3750
4000 4000
4250 4250
4500 4500
4750 4750
5000 5000

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0213 | UPS: Buffer time without action

Data type: UNSIGNED_16

Index: 24362

d

= 5F2A

h

Parameter | Name:

C0214 | UPS: Buffer time until shutdown

Data type: UNSIGNED_8

Index: 24361

d

= 5F29

h

After the time set here has elapsed, the system is shut down. If the voltage is applied once more, the system restarts

automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0

s

255 0 s

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0216 | UPS: Resp. after voltage failure

Data type: UNSIGNED_8

Index: 24359

d

= 5F27

h

Response of the system in the case of voltage failure
Selection list

(Lenze setting printed in bold)

Information

0 Switch-off
1 Reboot

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C0217 | UPS: Use ACPI

Data type: UNSIGNED_8

Index: 24358

d

= 5F26

h

Selection list

(Lenze setting printed in bold)

Information

0 No
1 Yes

;

Read access ; Write access … CINH … PLC STOP … No transfer