Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices – Lenze PC-based Automation Industrial PC User Manual
Page 140
![background image](/manuals/566344/140/background.png)
Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
140
L
2.5 EN - 01/2012
C0112
C0113
C0114
C0115
C0116
C0117
C0118
Parameter | Name:
C0112 | FTP: Home user 2
Data type: VISIBLE_STRING
Index: 24463
d
= 5F8F
h
Home directory of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0113 | WinCE-User: User 2 with telnet permissions
Data type: UNSIGNED_8
Index: 24462
d
= 5F8E
h
User may use telnet
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0114 | WinCE-User: User 2 with RAS permissions
Data type: UNSIGNED_8
Index: 24461
d
= 5F8D
h
User may use RAS
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0115 | WinCe users: User name 3
Data type: VISIBLE_STRING
Index: 24460
d
= 5F8C
h
Name of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0116 | WinCe users: Password 3
Data type: VISIBLE_STRING
Index: 24459
d
= 5F8B
h
Password of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0117 | WinCE users: User 3 with FTP permissions
Data type: UNSIGNED_8
Index: 24458
d
= 5F8A
h
User may use FTP
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0118 | FTP: Permissions user 3
Data type: UNSIGNED_32
Index: 24457
d
= 5F89
h
FTP rights of the user.
Value is bit-coded:
Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Allow Virtual Roots
Bit 3 Allow Hidden Files
;
Read access ; Write access CINH PLC STOP No transfer