Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices – Lenze PC-based Automation Industrial PC User Manual
Page 139
2.5 EN - 01/2012
L
139
Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
C0105
C0106
C0107
C0108
C0109
C0110
C0111
Parameter | Name:
C0105 | FTP: Home user 1
Data type: VISIBLE_STRING
Index: 24470
d
= 5F96
h
Home directory of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0106 | WinCE-User: User 1 with telnet permissions
Data type: UNSIGNED_8
Index: 24469
d
= 5F95
h
User may use telnet
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 1
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0107 | WinCE-User: User 1 with RAS permissions
Data type: UNSIGNED_8
Index: 24468
d
= 5F94
h
User may use RAS
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 1
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0108 | WinCe users: User name 2
Data type: VISIBLE_STRING
Index: 24467
d
= 5F93
h
Name of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0109 | WinCe users: Password 2
Data type: VISIBLE_STRING
Index: 24466
d
= 5F92
h
Password of the user
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0110 | WinCE users: User 2 with FTP permissions
Data type: UNSIGNED_8
Index: 24465
d
= 5F91
h
User may use FTP
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0111 | FTP: Permissions user 2
Data type: UNSIGNED_32
Index: 24464
d
= 5F90
h
FTP rights of the user.
Value is bit-coded:
Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Allow Virtual Roots
Bit 3 Allow Hidden Files
;
Read access ; Write access CINH PLC STOP No transfer