Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices – Lenze PC-based Automation Industrial PC User Manual
Page 135
2.5 EN - 01/2012
L
135
Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
C0075
C0076
C0078
C0079
C0090
C0091
Parameter | Name:
C0075 | Allocated virtual file memory
Data type: UNSIGNED_32
Index: 24500
d
= 5FB4
h
Object store reserved for saving of virtual files
Display range
(min. value | unit | max. value)
0
Bytes
4294967295
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0076 | Used virtual file memory
Data type: UNSIGNED_32
Index: 24499
d
= 5FB3
h
Object store occupied by virtual files
Display range
(min. value | unit | max. value)
0
Bytes
4294967295
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0078 | Allocated flash memory
Data type: UNSIGNED_32
Index: 24497
d
= 5FB1
h
Flash memory reserved
Display range
(min. value | unit | max. value)
0
Bytes
4294967295
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0079 | Used flash memory
Data type: UNSIGNED_32
Index: 24496
d
= 5FB0
h
Flash memory occupied
Display range
(min. value | unit | max. value)
0
Bytes
4294967295
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0090 | System: Date and time
Data type: DATE
Index: 24485
d
= 5FA5
h
Date and time
Setting range
(min. value | unit | max. value)
Lenze setting
NaN
;
Read access ; Write access CINH PLC STOP ; No transfer
Parameter | Name:
C0091 | Local date and time
Data type: DATE
Index: 24484
d
= 5FA4
h
Local date and time.
Setting range
(min. value | unit | max. value)
Lenze setting
NaN
;
Read access ; Write access CINH PLC STOP ; No transfer