Industrial pc | parameter setting & configuration, Parameter reference panel – Lenze PC-based Automation Industrial PC User Manual
Page 157

2.5 EN - 01/2012
L
157
Industrial PC | Parameter setting & configuration
Parameter reference
Panel
C0434
C0435
C0436
C0437
C0438
Parameter | Name:
C0434 | Key F2: Function
Data type: UNSIGNED_32
Index: 24141
d
= 5E4D
h
Assignment of F2 key function. The different functions are assigned via a selection list.
Selection list
(Lenze setting printed in bold)
Information
0 None
1 Start program
2 Touch keyboard
3 Right mouseclick
4 Run AP script
5 Start Control Panel
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0435 | Key F2: Parameter
Data type: VISIBLE_STRING
Index: 24140
d
= 5E4C
h
Name of the script or program to be executed
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0436 | Key F3: Function
Data type: UNSIGNED_32
Index: 24139
d
= 5E4B
h
Assignment of F3 key function. The different functions are assigned via a selection list.
Selection list
(Lenze setting printed in bold)
Information
0 None
1 Start program
2 Touch keyboard
3 Right mouseclick
4 Run AP script
5 Start Control Panel
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0437 | Key F3: Parameter
Data type: VISIBLE_STRING
Index: 24138
d
= 5E4A
h
Name of the script or program to be executed
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0438 | Key F4: Function
Data type: UNSIGNED_32
Index: 24137
d
= 5E49
h
Assignment of F4 key function. The different functions are assigned via a selection list.
Selection list
(Lenze setting printed in bold)
Information
0 None
1 Start program
2 Touch keyboard
3 Right mouseclick
4 Run AP script
5 Start Control Panel
;
Read access ; Write access CINH PLC STOP No transfer