Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices – Lenze PC-based Automation Industrial PC User Manual
Page 150

Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
150
L
2.5 EN - 01/2012
C0181
C0203
C0204
C0205
C0207
Parameter | Name:
C0181 | Telnet: Enabled
Data type: UNSIGNED_32
Index: 24394
d
= 5F4A
h
Activation of the telnet service
• Entering "1" activates the telnet service
• Entering "0" deactivates the telnet service
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 1
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0203 | UPS: UPS monitoring
Data type: UNSIGNED_8
Index: 24372
d
= 5F34
h
Selection list
(Lenze setting printed in bold)
Information
0 OFF
1 On
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0204 | UPS: Status
Data type: UNSIGNED_8
Index: 24371
d
= 5F33
h
Selection list
(read only)
Information
0 ACU controller missing
85 Battery/capacitor loaded
86 Battery/capacitor is loaded
87 -
88 -
89 UPS buffers system
90 Battery/capacitor short circuit
91 Battery/capacitor missing
92 Battery/capacitor defective
93 ACU controller defective
94 -
95 Battery/capacitor state undef.
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0205 | UPS: Supply voltage
Data type: FLOAT_32
Index: 24370
d
= 5F32
h
Display range
(min. value | unit | max. value)
0
V
34
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0207 | UPS: Battery/capacitor voltage
Data type: FLOAT_32
Index: 24368
d
= 5F30
h
Display range
(min. value | unit | max. value)
V
;
Read access Write access CINH PLC STOP No transfer