Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices – Lenze PC-based Automation Industrial PC User Manual
Page 151
![background image](/manuals/566344/151/background.png)
2.5 EN - 01/2012
L
151
Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
C0208
C0209
C0210
C0211
C0212
C0213
Parameter | Name:
C0208 | UPS: Display light after volt. fail.
Data type: UNSIGNED_8
Index: 24367
d
= 5F2F
h
Selection list
(Lenze setting printed in bold)
Information
0 OFF
1 On
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0209 | UPS: Number of voltage dips
Data type: UNSIGNED_8
Index: 24366
d
= 5F2E
h
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0210 | UPS: Supply voltage OK
Data type: UNSIGNED_8
Index: 24365
d
= 5F2D
h
Selection list
(read only)
Information
0 No
1 Yes
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0211 | UPS: Voltage failure
Data type: UNSIGNED_8
Index: 24364
d
= 5F2C
h
Selection list
(read only)
Information
0 No
1 Yes
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0212 | UPS: Firmware version
Data type: VISIBLE_STRING
Index: 24363
d
= 5F2B
h
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C0213 | UPS: Buffer time without action
Data type: UNSIGNED_16
Index: 24362
d
= 5F2A
h
The UPS buffers the system without further action. If the voltage dip takes longer than the time set here:
• The PLC is stopped.
• The PLC saves the retain variables, logbook entries and visualisation data (trends and alarms).
• The timer
is started.
Selection list
(Lenze setting printed in bold)
Information
0 0
250 250
500 500
750 750
1000 1000
1250 1250
1500 1500
1750 1750
2000 2000
2250 2250