C0018, Can be executed, C0019 – Lenze PC-based Automation Industrial PC User Manual
Page 130: Displays stat, Industrial pc | parameter setting & configuration, Parameter reference parameters of standard devices

Industrial PC | Parameter setting & configuration
Parameter reference
Parameters of standard devices
130
L
2.5 EN - 01/2012
C0016
C0018
C0019
Parameter | Name:
C0016 | System identification: Description
Data type: VISIBLE_STRING
Index: 24559
d
= 5FEF
h
Description for the identification on the system
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C0018 | Command
Data type: UNSIGNED_16
Index: 24557
d
= 5FED
h
Load PLC program command. Here the PLC boot project is reloaded.
Selection list
(Lenze setting printed in bold)
Information
0 No command
256 Exit
Close the data manager
279 Persist all
Save the data from the following tables to the
management data base:
• Data of the object table
• Data of all address tables
• Data of the file table
287 Restore all
Replace the following tables by the corresponding tables
in the management data base:
• The object table
• All address tables
• The file table
The old lists will be deleted permanently.
302 Delete logbook
512 Start PLC
513 Stop PLC
515 PLC: Reload boot project
1281 Purge
Delete all files which are in the file system of the data
manager and not registered in the file table.
1282 Persist logbook
Save the logbook with all entries to a log file
1538 Start FTP server
1539 Stop FTP server
1560 Update FTP server
1540 Start telnet server
1541 Stop telnet server
1561 Update telnet server
1542 Start web server
1543 Stop web server
1562 Update web server
1544 Start RAS server
1545 Stop RAS server
1563 Update RAS server
;
Read access ; Write access CINH PLC STOP ; No transfer
Parameter | Name:
C0019 | Command status
Data type: UNSIGNED_16
Index: 24556
d
= 5FEC
h
Code with the status of the running command
Display range
(min. value | unit | max. value)
;
Read access Write access CINH PLC STOP No transfer