Industrial pc | parameter setting & configuration – Lenze PC-based Automation Industrial PC User Manual
Page 164
![background image](/manuals/566344/164/background.png)
Industrial PC | Parameter setting & configuration
Parameter reference
Industrial PC extension modules
164
L
2.5 EN - 01/2012
C1091
C1092
C1093
C1094
C1096
C1098
Parameter | Name:
C1091 | Rx PDO counter
Data type: UNSIGNED_32
Index: 23484
d
= 5BBC
h
PDO counter for received CAN messages
Display range
(min. value | unit | max. value)
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1092 | Bus load
Data type: UNSIGNED_32
Index: 23483
d
= 5BBB
h
Specification of the average bus load. The bus load is calculated as follows: Bus load = Value in percent x 1000
Display range
(min. value | unit | max. value)
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1093 | Error counter
Data type: UNSIGNED_32
Index: 23482
d
= 5BBA
h
Error counter since last initialisation of the CAN interface
Display range
(min. value | unit | max. value)
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1094 | Last error code
Data type: UNSIGNED_32
Index: 23481
d
= 5BB9
h
Code of the last error that occurred
Display range
(min. value | unit | max. value)
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1096 | CAN node ID
Data type: UNSIGNED_8
Index: 23479
d
= 5BB7
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
128 63
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C1098 | Channel
Data type: UNSIGNED_32
Index: 23477
d
= 5BB5
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
;
Read access ; Write access CINH PLC STOP No transfer