Industrial pc | parameter setting & configuration, Parameters of the card in slot 2 – Lenze PC-based Automation Industrial PC User Manual
Page 189

2.5 EN - 01/2012
L
189
Industrial PC | Parameter setting & configuration
Parameter reference
Industrial PC extension modules
C1096/35
C1096/36
C1096/37
C1096/38
Parameters of the card in slot 2
C1531
C1532
C1533
Parameter | Name:
C1096/35 | ECAT: Lost link counter - port 0
Data type: UNSIGNED_8
Index: 23479.35
d
=
0x5BB7.0x23
h
Number of lost links at port 0.
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1096/36 | ECAT: Lost link counter - port 1
Data type: UNSIGNED_8
Index: 23479.36
d
=
0x5BB7.0x24
h
Number of lost links at port 1.
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1096/37 | ECAT: Lost link counter - port 2
Data type: UNSIGNED_8
Index: 23479.37
d
=
0x5BB7.0x25
h
Number of lost links at port 2.
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1096/38 | ECAT: Lost link counter - port 3
Data type: UNSIGNED_8
Index: 23479.38
d
=
0x5BB7.0x26
h
Number of lost links at port 3.
Display range
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1531 | Device: Type key
Data type: VISIBLE_STRING
Index: 23044
d
= 5A04
h
Card identification
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1532 | Device: Type version
Data type: VISIBLE_STRING
Index: 23043
d
= 5A03
h
Version number of the card
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1533 | Device: Name
Data type: VISIBLE_STRING
Index: 23042
d
= 5A02
h
Device name of the card
;
Read access Write access CINH PLC STOP No transfer