Show system – Allied Telesis AT-S63 User Manual
Page 99

AT-S63 Management Software Command Line User’s Guide
Section I: Basic Operations
99
SHOW SYSTEM
Syntax
show system
Parameters
None.
Description
This command displays the following information:
MAC Address: The MAC address of the switch.
Model Name: The model name of the switch.
Serial Number: The serial number of the switch.
IP Address: The IP address of the local interface.
Subnet Mask: The subnet mask of the local interface.
System Up Time: The length of time since the switch was last reset or
power cycled.
Bootloader: The version number and build date of the AT-S63
bootloader.
Application: The version number and build date of the AT-S63
Management Software.
System Name: The name of the switch.
Administrator: The name of the network administrator responsible for
managing the switch.
Location: The location of the switch, (for example, 4th Floor - rm
402B).
Note
To configure the name, administrator, and location parameters, refer
to “SET SYSTEM” on page 85.
Power Information: The status of the main power supply, the
redundant power supply (if present), and internal power consumption.
Temperature (Deg.C): The ambient temperature as measured where
the air enters the cooling vents on the side of the unit.
Fan Information: The speed or operating status of the system fan(s).
Command
Available
AlliedWare Plus