Alliedware plus command – Allied Telesis AT-S63 User Manual
Page 332

Chapter 17: Event Log and Syslog Client Commands
332
Section II: Advanced Operations
An example of the information displayed by this command with the FULL
parameter is shown in Figure 53.
Figure 53. SHOW LOG OUTPUT Command with the FULL Parameter
For definitions of the parameters, refer to “SET LOG OUTPUT” on
page 322.
Examples
The following command lists all the output definitions:
show log output
The following command displays the details of output definition number 5:
show log output=5 full
AlliedWare Plus
Command
Syntax
show log config
Modes
User Exec mode and Privileged Exec mode
Description
This AlliedWare Plus command lists the current settings of the two event
logs and any syslog definitions, and is equivalent to the standard
command without the FULL parameter. An example of the information the
command displays is shown in Figure 52 on page 331. This command
cannot display detailed information about the syslog definitions because it
does not have an equivalent parameter for the FULL parameter in the
standard command.
Example
awplus# show log config
Output ID .................... 2
Output Type .................. Syslog
Status ....................... Enabled
Server IP Address ............ 149.88.88.88
Message Format ............... Extended
Facility Level ............... DEFAULT
Event Severity ............... E,W,I
Event Module ................. All