Message ID
Message Text
Explanation
If the same error occurs, re-install
HDLM. For details on the view
operation, see
. For
details on the set operation, see
KAPL04010-E
Could not open the error log file. Details
HDLM manager cannot start
normally (unable to open the error
log file /var/opt/
DynamicLinkManager/log/
dlmmgr[1-16].log).
Action
Check whether another program is
using the file (for example, the file
is being opened in a text editor),
or whether the error log file has
been inadvertently deleted.
KAPL04011-E
Could not output the error log
file.
Details
The log information could not be
output to the error log file /var/
opt/DynamicLinkManager/log/
dlmmgr[1-16].log.
Action
Make sure that the disk has
enough unused capacity.
KAPL04012-E
Could not create a
communication pipe. RC =
aa...aa
Details
HDLM manager could not start
normally because it was unable to
create a pipe file, which is used in
communication with HDLM
commands.
aa...aa: OS error code(decimal
(base-10) number)
Action
Execute the DLMgetras utility for
collecting HDLM error information,
and then contact your HDLM
vendor or the maintenance
company if there is a maintenance
contract for HDLM. For details on
the DLMgetras utility, see
DLMgetras Utility for Collecting
HDLM Error Information on page
.
KAPL04013-E
Input is impossible via the
communication pipe. RC =
aa...aa
Details
Data could not be read from the
pipe file while communicating with
an HDLM command.
Messages
8-33
Hitachi Dynamic Link Manager User Guide for Linux
®