beautypg.com

Canceling the md device settings, Canceling the md device settings -241, Canceling the md – HP Hitachi Dynamic Link Manager Software User Manual

Page 313

background image

9

.

Execute the pvscan command to check that the environment has been

changed successfully.
The following shows an example of executing the pvscan command:

# pvscan

PV /dev/sda1 VG vg01 lvm2 [468.00 MB / 368.00 MB free]

PV /dev/sda2 VG vg01 lvm2 [548.00 MB / 548.00 MB free]

Total: 2 [1016.00 MB] / in use: 2 [1016.00 MB] / in no VG: 0

[0 ]

10

.

Activate the volume group.
In the following example, the logical volume subject to the move belongs

to the vg01 volume group:

# vgchange -ay vg01

1 logical volume(s) in volume group "vg01" now active

11

.

If the /etc/fstab file was edited (a section was commented out) in step

5, return the commented out section to its original state.

12

.

Mount the logical volume that was moved.
In the following example, the logical volume that was moved is /dev/
vg01/lvol1 and the command mounts the volume on /mnt/lvol1:

# mount /dev/vg01/lvol1 /mnt/lvol1

Canceling the md Device Settings

This subsection describes how to migrate an environment where the md

devices were constructed by using HDLM-managed devices to an environment

where the md devices were constructed by using SCSI devices.

When md devices have been constructed by using SCSI devices, if you do not

use the MULTIPATH function for the md devices, perform the procedure

described in

Migrating to md Devices for which the MULTIPATH Function Is

Not Used on page 3-241

. If you want to use the MULTIPATH function for the

md devices, perform the procedure described in

Migrating to md Devices for

which the MULTIPATH Function Is Used on page 3-244

.

Migrating to md Devices for which the MULTIPATH Function Is Not Used

This section describes the procedure for migrating an environment where the

md devices were created on an HDLM device to an environment where the

md devices were created on a SCSI device, by using an example where the

RAID functionality is used for the md devices.

In this procedure, the device /dev/md0 on /dev/sddlmaa1 and /dev/
sddlmab1 is migrated to the device /dev/md0 on /dev/sdh1 and /dev/sdi1.

Use the following procedure to configure the environment shown in

Figure

3-39 Device Configuration When an md Device on an HDLM Device Is Moved

Creating an HDLM Environment

3-241

Hitachi Dynamic Link Manager User Guide for Linux

®

This manual is related to the following products: