Key name

#1

Description

#2

Necessity of

definition

Maxim

um

numbe

r of

charac

ters

New

installa

tion

Upgrad

e

installa

tion or

re-

installa

tion

path_health_check

Specify one of the following values

to indicate whether to enable or

disable the path health check

function:
on: Enabled (default)

off: Disabled

Optional Optional 3

path_health_check_
interval

Specify the interval in minutes at

which the path health check is

performed.
You can specify a check interval

from 1 to 1440. The default is 30.

Optional Optional 4

auto_failback

Specify one of the following values

to indicate whether to enable or

disable the automatic failback

function for failed paths:
on: Enabled (default)

off: Disabled

Optional Optional 3

auto_failback_inte
rval

Specify the interval in minutes from

the time the previous path status

check finished until the time the

next path status check started.
You can specify a check interval

from 1 to 1440. The default is 1.

Optional Optional 4

intermittent_error
_monitor

#3

Specify one of the following values

to indicate whether to enable or

disable intermittent error

monitoring:
on: Enabled

off: Disabled (default)

Optional Optional 3

intermittent_error
_monitor_interval

Specify the interval in minutes that

monitoring for intermittent errors is

performed.
You can specify a check interval

from 1 to 1440. The default is 30.

Optional Optional 4

intermittent_error
_monitor_number

Specify the number of times an

error occurs. You can specify a

value from 1 to 99. The default is 3.

Optional Optional 2

dynamic_io_path_co
ntrol

Specify whether to enable or

disable the dynamic I/O path

Optional Optional 3

7-48