HP Hitachi Dynamic Link Manager Software User Manual
Page 521
Message ID
Message Text
Explanation
view (Displays Information) on
.
KAPL01024-W The specified parameters cannot
be specified at the same time.
Operation name = aa...aa,
parameters = bb...bb
Details
aa...aa: clear, offline, online,
set, or view
bb...bb: Parameters that cannot
be specified at the same time
Action
Execute help operation of the
HDLM command (dlnkmgr) to
check which parameters can be
specified at the same time, and
then retry. For details on the help
operation, see
KAPL01036-E
The Offline path cannot be
placed online. PathID = aa...aa
Details
aa...aa: Path ID (decimal
(base-10) number)
Action
Remove the error in the path, and
then retry.
KAPL01039-W During the online operation
processing of the HDLM
command, a path that cannot be
placed in the Online status was
detected. PathID = aa...aa
Would you like to continue the
processing of the online
operation? [y/n]:
Details
A path that cannot be placed
Online was detected during multi-
path online processing.
To ignore this path and perform
online processing for the next
path, enter y.
To cancel processing, enter n.
aa...aa: Path ID (decimal
(base-10) number)
Action
If you want to continue processing
of the online operation of the
HDLM command for other paths,
enter y. If you want to terminate
processing, enter n. For details on
the online operation, see
.
KAPL01040-W The entered value is invalid. Re-
enter [y/n]:
Details
A value other than y and n was
entered. Enter y or n.
Action
Enter y or n.
Messages
8-9
Hitachi Dynamic Link Manager User Guide for Linux
®