beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 364

background image

Figure 4-2 System Configuration for Replacing a Fiber Cable (Explained in

the Following Steps)

To replace a fiber cable:

1

.

Place in Offline (C) status the path that goes through the fiber cable to be

replaced (path that goes through the HBA to which the fiber cable is

connected).
For example, to place in Offline (C) status the path that goes through the

HBA with host port number 0001 and bus number 0000, execute the

following command:

# /opt/DynamicLinkManager/bin/dlnkmgr offline -hba 0001.0000

While the path that goes through the HBA with host port number 0001 is

placed Offline, the status of the path that goes through the HBA with host

port number 0002 is Online.

4-32

HDLM Operation

Hitachi Dynamic Link Manager User Guide for Linux

®

This manual is related to the following products: