The HP VMA SAN Gateway chassis has two single-phase power supplies installed
prior to shipping. The IEC-C14 male receptacles accept two IEC-C13 female
connectors.
Each HP VMA SAN Gateway features redundant power supplies. Connect the AC
power cord to either power receptacle on the HP VMA SAN Gateway or both.
For maximum availability, the power supplies for each HP VMA SAN Gateway
and HP VMA Array should be connected to different power feeds to provide
failover in case of a failed power supply or loss of a power feed.
In a typical system containing two HP VMA SAN Gateways and two Memory
Arrays, eight 208V outlets are recommended.
Connecting Network Interfaces
You can connect to the VMA-series SAN Gateway using the following methods:
•
APC and a null modem cable.
•
A keyboard, video monitor, and mouse (KVM) connected directly to the HP
VMA SAN Gateway.
•
A Virtual serial text console or Integrated Remote Management (VGA)
console through the iLO interface
.
Figure 2.4 HP VMA SAN Gateway Power Supplies