HP VMA-series Memory Arrays User Manual
Page 72
72
AM456-9007B Rev 02
HP VMA SAN Gateway Installation and User Guide
A message confirms that the VMA Array was successfully initialized.
Viewing Containers
Once you have initialized the VMA Array, you can see the container created using
the
show containers
command.
1.
Log on as an administrator into the HP VMA SAN Gateway attached to Port 1
of the VMA Array.
Before a block media device can be used for block storage, it must be enabled.
Use the
media block id
command to enable the device.
2.
Enter into Config mode using the
configure terminal
command.
3.
Run the
media block id
command to enable all block
containers.
The
block
parameter ensures that you enable vSHARE devices and not
vCACHE devices. The
all
parameter ensures that every block container is
enabled.
4.
To verify the containers were created, run the
show containers
command
to view information about the containers.
media init completed successfully
SM076 [NJ-Lab-vSHARE00: standby] (config) #
# configure terminal
(config) #
(config) # media
(config) # media block id all enable
> enable
# show containers
Container LUNs Total Free Ports HostnameA HostnameB Status
---------------------------------------------------------------------------
C-1 0 199G 199G A,B
C-2 150 199G 50176M A,B