beautypg.com

HP VMA-series Memory Arrays User Manual

Page 72

background image

72

AM456-9007B Rev 02

HP VMA SAN Gateway Installation and User Guide

A message confirms that the VMA Array was successfully initialized.

Viewing Containers

Once you have initialized the VMA Array, you can see the container created using

the

show containers

command.

1.

Log on as an administrator into the HP VMA SAN Gateway attached to Port 1

of the VMA Array.

Before a block media device can be used for block storage, it must be enabled.

Use the

media block id enable

command to enable the device.

2.

Enter into Config mode using the

configure terminal

command.

3.

Run the

media block id enable

command to enable all block

containers.

The

block

parameter ensures that you enable vSHARE devices and not

vCACHE devices. The

all

parameter ensures that every block container is

enabled.

4.

To verify the containers were created, run the

show containers

command

to view information about the containers.

media init completed successfully

SM076 [NJ-Lab-vSHARE00: standby] (config) #

# configure terminal
(config) #

(config) # media
(config) # media block id all enable

> enable
# show containers
Container LUNs Total Free Ports HostnameA HostnameB Status
---------------------------------------------------------------------------
C-1 0 199G 199G A,B Single
C-2 150 199G 50176M A,B Single