beautypg.com

Event notification – HP VMA-series Memory Arrays User Manual

Page 131

background image

AM456-9007B Rev 02

HP VMA SAN Gateway Installation and User Guide

131

Disable or re-enable an NTP server or peer. Servers and peers start enabled;

disabling is just a way of making them temporarily inactive without losing their

configuration.

[no] ntp enable
[no] ntp disable

Enable or disable NTP overall. Note that the latter is the Cisco command; the

former is just a pair of aliases added to increase usability, as otherwise it may be

hard for a user to figure out how to enable NTP if they are not aware of

no

commands and only see a way to disable it.

show ntp

Display current NTP settings.

Event Notification

[no] email enable

Enable or disable the sending of e-mail when certain events occur. These events are

the same as those for which SNMP traps can be sent (see

SNMP Configuration

on

page 162).

email mailhub
no email mailhub

Set or clear the mail relay to use to send notification emails.

email mailhub-port
no email mailhub-port

Set the mail relay port to use to send notification emails. The

no

variant resets the

port to its default, which is 25.

email domain
no email domain

Set the domain name to be used as the source for e-mail notifications. The specified

domain name is used in conjunction with the system hostname to form the source

e-mail address.

The rules are as follows: