HP VMA-series Memory Arrays User Manual
Page 244

244
AM456-9007B Rev 02
HP VMA SAN Gateway Installation and User Guide
cpu-util-high
98
Percent
an HP VMA SAN Gateway
has detected that a CPU has
exceeded utilization above
the threshold level
Please contact HP customer
support if the system is not
under full data traffic load.
Low
disk-space-low
0
Percent
Free
an HP VMA SAN Gateway
disk space has crossed the
threshold of percent of bytes
free.
Please contact HP customer
support.
Medium
interface-down
Event
Triggered
A network interface on an
HP VMA SAN Gateway has
lost link.
Check the network cables to
the HP VMA SAN
Gateway.
High
interface-up
Event
Triggered
A network interface on an
HP VMA SAN Gateway has
detected link up.
Nothing.
Low
lid-ajar-time-high
60
Seconds
A VMA Array chassis lid is
open
Verify VMA Array chassis
lid is closed
High
lid-ajar-time-ok
1
Seconds
A VMA Array chassis lid
has been closed for at least
this period
Nothing.
Low
liveness-failure
Event
Triggered
An internal process on an
HP VMA SAN Gateway has
been detected as hung.
Please contact HP customer
support
High
paging-high
2000
Duration /
sec
Memory paging on an HP
VMA SAN Gateway has
exceeded a threshold.
Please contact HP customer
support if the system is not
under full data traffic load.
Medium
process-crash
Event
Triggered
An internal process on an
HP VMA SAN Gateway has
crashed. A callhome event
is generated with the details
of the event.
Please contact HP customer
support.
High
process-exit
Event
Triggered
An internal process on an
HP VMA SAN Gateway has
unexpectedly exited. A
callhome event is generated
with the details of the event.
Please contact HP customer
support.
High
unexpected-shutdown
Event
Triggered
an HP VMA SAN Gateway
has unexpectedly shutdown.
This may happen during a
software upgrade when the
upgrade did not cleanly
apply and the system
reverted back to the
previous version prior to
upgrade. A callhome event
is generated.
Please contact HP customer
support.
High