Trap information table – HP VMA-series Memory Arrays User Manual
Page 243
AM456-9007B Rev 02
HP VMA SAN Gateway Installation and User Guide
243
Trap Information Table
Trap Name
Threshold
Value Unit
Description
Recommendation
Severity
array-data-plane-ready
State Change
0 or 1
A VMA Array data plane
available state change has
occurred. The old value and
new values are supplied. A
value of 0 = not ready, 1 =
ready.
If the new value is 0, then
check the VMA Array
alarms for more
information.
High / Low
array-led-change
State Change
State
One or more of the LEDs on
a VMA Array has changed
state. The following LEDs
are tracked for state change:
Alarm, PowerA, PowerB,
and Status. The LED values
are: OFF, SLOW_BLINK,
FAST_BLINK, or ON.
If the new value is OFF for
either Power LED, then
check power cables. If
Status LED is anything but
ON, or Alarm LED is
anything but OFF, then
check the VMA Array for
alarms.
High / Low
array-pcie-link-down
Event
Triggered
The VMA Array specified
in the trap has detected a
PCIe link loss.
Check the PCIe cable
between the VMA Array
and the HP VMA SAN
Gateway.
High
array-pcie-link-up
Event
Triggered
The VMA Array specified
in the trap has detected that
the PCie link has gone
active.
Nothing.
Low
array-psu-state
State Change
State
A VMA Array has changed
state regarding one or both
of the Power Supply Units.
A true or false value for
psuA and psuB specifies
whether the old / new values
are different. The PSU state
can be: Absent, ON, or OFF.
Check the power source to
the VMA Array power
supplies.
High / Low
array-raid-rebuild
State Change
0 or 1
A VMA Array has changed
state regarding VIMM
RAID group rebuild. A new
value of 1 specifies that a
RAID rebuild is in progress
and that performance will be
affected. A new value of 0
specifies that the RAID
rebuild has completed.
If the new value is 1, check
the VMA Array alarms for a
failed VIMM and contact
HP support for a possible
replacement.
Medium
chassis-temperature-high
75
Celsius
Temperature inside a VMA
Array chassis has exceeded
normal operating range
Check airflow and operating
environment.
High
chassis-temperature-ok
70
Celsius
Temperature inside a VMA
Array chassis has dropped
into normal operating range
Nothing.
Low