HP VMA-series Memory Arrays User Manual
Page 45
![background image](/manuals/397492/45/background.png)
AM456-9007B Rev 02
HP VMA SAN Gateway Installation and User Guide
45
previously configured). After the last step, the wizard repeats your settings and lets
you return to any step if you want to make more changes.
To rerun the Configuration Wizard, use the command
configuration jump-
start
from the CLI(confg) prompt
.
To configure the Master HP VMA SAN Gateway using the configuration
wizard:
1.
Connect and log in as admin.
The configuration wizard prompts you to use it for the initial configuration of
the HP VMA SAN Gateway.
2.
Respond "Yes" to the wizard prompt.
You are prompted to answer a series of configuration questions. The responses
given for each question will configure the initial HP VMA SAN Gateway,
which becomes the master node.
3.
Reply “Yes” to Step 1: Configure as master/stand-alone?
By replying Yes, you define the current HP VMA SAN Gateway as the master
node of the cluster. You should answer Yes only for the master node or
standalone gateways. Answer No for all other nodes. There is a shorter list of
questions for the other nodes compared to the master node. A standby node will
be elected from the remaining nodes that form the vCLUSTER.
4.
In each subsequent step, type a new value or press the Enter key to accept the
default value shown in square brackets (if one is present).
Do you want to use the wizard for initial configuration?
Yes
Step 1: Configure as master/stand-alone? [yes]