CONFIGURATION

139

DC coupling

AC coupling

Input Impedance

Background

The input impedance of the GDS-2000A is fixed at
1MΩ. The impedance is displayed in the channel
menu.

View Impedance

1. Press the Channel key.

CH1

2. The impedance is displayed in the

bottom menu.

Invert Waveform Vertically

Panel Operation

1. Press the Channel key.

CH1

2. Repeatedly press Invert to toggle

Invert On or Off.