IAI America PCON-CF User Manual
Page 79
61
5. I/O Signal Control and Signal Functions
Movement to each position (ST0 to ST2) [3-point type]
Since the number of positioning points is limited to three, the actuator can be controlled just like an air cylinder.
While this signal is ON, the actuator will move toward the target position.
If the signal turns OFF while the actuator is moving, the actuator will decelerate to a stop.
Before executing this command, enter a target position in the “Position” field for position No. 0, 1 or 2 in the
position table.
Input signal
Target position
Remarks
ST0
Rear end
The target position is defined in the “Position” field for position No. 0.
ST1
Front end
The target position is defined in the “Position” field for position No. 1.
ST2
Intermediate point The target position is defined in the “Position” field for position No. 2.