Caution – IAI America PCON-CF User Manual
Page 5
![background image](/manuals/350314/5/background.png)
CAUTION
x
Changes to Zone Function
Applicable application versions: V0016 and later
Among the zone signal settings, those that result in “Zone setting+ < Zone setting-” are now effective.
V0015 and earlier: “Zone setting+
d Zone setting-” o A zone signal is not output.
V0016 and later: “Zone setting+ = Zone setting-”
o This is the only condition in which a zone signal is not output.
Accordingly, you can now output a zone signal even when a rotary actuator is operated over the 0
q position in
the index mode.
An example is given below.
[Rotary actuator in index mode]
Set value
Set value
Zone setting+: 70
q
Zone setting+: 315
q
Zone setting-: 315
q
Zone setting-: 70
q
[Linear axis]
Current position
Zone signal output
Zone signal output
Zone signal ON range
Set value
Zone setting+: 70 mm
Zone setting-: 30 mm
Set value
Zone setting+: 30 mm
Zone setting-: 70 mm