128

8. Parameter Settings

8. Parameter

Settings

8.1 Parameter

Table

Category:

a: Parameter relating to the actuator stroke range
b: Parameter relating to the actuator operating characteristics
c: Parameter relating to the external interface
d: Servo gain adjustment

No. Category Symbol

Name

Unit

Default factory setting

1

a

ZONM Zone boundary 1+

mm

Effective actuator length

2

a

ZONL Zone boundary 1–

mm

Effective actuator length

3

a

LIMM

Soft limit+

mm

Effective actuator length

4

a

LIML

Soft limit–

mm

Effective actuator length

5 a ORG

Home return direction
[0: Reverse / 1: Forward]

-

(In accordance with the specification at the
time of order)

6

b

PSWT Push & hold stop judgment period

msec

255

7

d

PLG0 Servo gain number

-

6

8 b VCMD

Default

speed

mm/sec

Set individually in accordance with the
actuator characteristics.

9 b ACMD

Default

acceleration/deceleration

G

Set individually in accordance with the
actuator characteristics.

10

b

INP

Default positioning band (in-position)

mm

Set individually in accordance with the
actuator characteristics.

12 b SPOW Current-limiting value at standstill during positioning

%

60

13 b ODPW Current-limiting value during home return

%

Set individually in accordance with the
actuator characteristics.

15

c

FPIO

Pause input disable selection [0: Enable / 1: Disable]

-

0 [Enable]

16

c

BRSL SIO communication speed

bps

38400

17 c RTIM

Minimum delay time for slave transmitter activation

msec 5

18 b LS

Home sensor input polarity

-

Set individually in accordance with the
actuator characteristics.

21 c SON

Servo ON input
[0: Enable / 1: Disable]

0

22

a

OFST Home return offset

mm

Set individually in accordance with the
actuator characteristics.

23

a

ZNM2 Zone boundary 2+

mm

Effective actuator length

24

a

ZNL2

Zone boundary 2–

mm

Effective actuator length

25

c

IOPN

PIO pattern selection

-

0 [Standard type]

26

b

IOJV

PIO jog speed

mm/sec

100

27 c FPIO

Movement command type
[0: Level / 1: Edge]

-

0 [Level]

28 b PHSP

Default direction of excited-phase signal detection
[0: Reverse / 1: Forward]

Set individually in accordance with the
actuator characteristics.

29

b

PHSP Excited-phase signal detection time

msec

Set individually in accordance with the
actuator characteristics.

31

d

VLPG Speed loop proportional gain

-

Set individually in accordance with the
actuator characteristics.

32

d

VLPT

Speed loop integral gain

-

Set individually in accordance with the
actuator characteristics.

33

d

TRQF Torque filter time constant

-

Set individually in accordance with the
actuator characteristics.

34 b PSHV

Push

speed

mm/sec

Set individually in accordance with the
actuator characteristics.

35 b SAFV

Safety

speed

mm/sec

100

36

b

ASO1 Automatic servo-off delay time 1

sec

0

37

b

ASO2 Automatic servo-off delay time 2

sec

0

38

b

ASO3 Automatic servo-off delay time 3

sec

0

39 c FPIO

Output mode of position complete signal
[0: PEND / 1: INP]

-

0 [PEND]

40 c HOME

Home-return input disable selection
[0: Enable / 1: Disable]

-

0 [Enable]