beautypg.com

IAI America PCON-CF User Manual

Page 31

background image

13

1. Overview

1.4 Procedure from Unpacking to Test Operation and Adjustment

If you are using this product for the first time, carry out each step by referring to the procedure below to ensure
that all necessary items are checked and all wires are connected correctly.

1

Check the content in the package

If you found any missing part or part specified for a different model, please contact your dealer.
z Controller

PCON-C
PCON-CG
PCON-CF

z Actuator

z I/O flat cable

CB-PAC PIO* * *

z Motor cable

CB-RCP2-MA* * *

z Encoder cable

CB-RCP2-PA* * *

z Operation manual


z Teaching pendant

z PC software

RCM-T (standard)

RC232C type

RCM-E (simple)

RC232 type

RCM-P (data setting unit)

(Software comes with connection cables.)

2

Installation

[1] Affix the actuator first, and then install the robot hand.

o Refer to the operation manual for the applicable

actuator.

[2] Install the controller.

o Chapter 3, “Installation”

3

Wiring/connection

x Wire the 24-V power supply.
x Connect the grounding wire to ground.
x Wire the emergency stop circuit and motor drive power supply.
x Connect the motor cable and encoder cable.
x Connect the I/O flat cable.

4

Turn on the power and check for alarms

Supply the 24-V power after confirming that the emergency stop circuit is not actuated.
If the monitor LED [SV/ALM] on the front face of the controller illuminates for two seconds and then turns off, the
controller is functioning properly. If [SV/ALM] illuminates in red, it means an alarm has generated. Connect a PC
or teaching pendant to check the nature of the alarm, and remove the cause by referring to Chapter 10,
“Troubleshooting.”

5

Set the PIO pattern/safety speed

Set the mode selector switch on the front face of the controller to the “MANU” side.
On the PC screen or teaching pendant, set the MANU operating mode to [Teaching mode: Enable safety
speed/Inhibit PIOs].
In this condition, set appropriate values in parameter No. 25 (PIO pattern selection) and parameter No. 35
(Safety speed).
* The factory-set PIO pattern and safety speed are “standard type” and “100 mm/s or less,” respectively.

o

Chapter 8, “Parameter Settings”

This manual is related to the following products: