9.3 Address

Switch

Set an address (0 to 15) as a hexadecimal (0 to F) using the ADRS switch on the front panel of each controller to
define the slave number for the controller.
Assign “0” to the controller nearest the host, and then assign 1, 2, 3, …, E and F to the remaining controllers in
the direction of moving away from the host.
After all addresses have been set, reconnect the power.

Caution: After the setting, be sure to confirm that the addresses are not duplicated.

9.4 Connection

Cables

z Controller link cable

Model number: CB-RCB-CTL002

(Reference) Connection

diagram for RS232C cross cable

SIO converter end

PC end

Signal No.

No.

Signal

SGA 1

1 SGA

SGB 2

2 SGB

+5V 3

3 GND

EMB 4

4

EMGA 5

+24V 6

GND 7

EMGB 8

Signal No.

1

RD 2
SD 3

DTR 4

SG 5

DSR 6

RS 7
CS 8

9

No.

Signal

1
2 RD
3 SD
4 DTR
5 SG
6 DSR
7 RS
8 CS
9

Controller end

200 mm

Mini DIN connector

E-Con connector

3-1473562-4

(Housing color: Orange)

Yellow

Orange

Blue

Adjust the arrow to a desired
position using a flathead
screwdriver.

D-sub, 9-pin female connector

D-sub, 9-pin
(Female connector for PC,
Male connector for PLC)

1 2

3 5

6 8