Installation and noise elimination, 1 installation environment, 2 power supply – IAI America PCON-CF User Manual
Page 39
21
3. Installation and Noise Elimination
3.
Installation and Noise Elimination
Pay due attention to the installation environment of the controller.
3.1
Installation Environment
3.2
Power Supply
The power supply specification is 24 VDC
r 10%.
(Supply current: 2 A max.: C/CG, 6 A: CF)
This product is capable for use in the environment of pollution degree 2
*1
or equivalent.
*1 Pollution Degree 2 : Environment that may cause non-conductive pollution or transient conductive pollution
by frost (IEC60664-1)
[1] Installation Environment
Do not use this product in the following environment.
• Location where the surrounding air temperature exceeds the range of 0 to 40°C
• Location where condensation occurs due to abrupt temperature changes
• Location where relative humidity exceeds 85%RH
• Location exposed to corrosive gases or combustible gases
• Location exposed to significant amount of dust, salt or iron powder
• Location subject to direct vibration or impact
• Location exposed to direct sunlight
• Location where the product may come in contact with water, oil or chemical droplets
• Environment that blocks the air vent [Refer to 3.3 Noise Elimination and Grounding]
When using the product in any of the locations specified below, provide a sufficient shield.
• Location subject to electrostatic noise
• Location where high electrical or magnetic field is present
• Location with the mains or power lines passing nearby
[2] Storage and Preservation Environment
• Storage and preservation environment follows the installation environment. Especially, when the product is
to be left for a long time, pay special attention to condensed water.
Unless specially specified, moisture absorbency protection is not included in the package when the machine
is delivered. In the case that the machine is to be stored in an environment where dew condensation is
anticipated, take the condensation preventive measures from outside of the entire package, or directly after
opening the package.