7. Operation

7.8 Zone Signal Output

Two types of zone output signals are available: zone output (ZONE1) and position zone output (PZONE). The
boundaries defining the signal ON range are set differently for each zone output.
[1] Zone output (ZONE1) --- Set by parameter No. 1/No. 2.
[2] Position zone output (PZONE) --- Set in the “Zone boundary-“ and “Zone boundary+” fields of the position

table.

Whether these signals are available or not varies depending on the PIO pattern, as shown below.

{: Available / x: Not available

PIO pattern

Signal classification

0 1 2 3 4 5

Zone output (ZONE1)

{

x x x

{

{

Position zone output (PZONE)

{

{

{

x

{

{

Example of use in operation) Move the actuator from the home to the 150-mm position (position 1) and output a

zone signal once the actuator enters the range between 40 mm and 120 mm.

Method)

x Zone output (ZONE1)

The signal ON range is set by the “Zone boundary+” and “Zone boundary-”
parameters.

Parameter No. 1

Zone boundary+

120 (mm)

Parameter No. 2

Zone boundary–

40 (mm)

x Position zone output (PZONE)

The signal ON range is set in the “Zone boundary+” and “Zone boundary-”
fields of the position table.

No.

Position

[mm]

Zone boundary+

[mm]

Zone boundary-

[mm]

0

*

*

*

1 150.00

120.00

40.00