55

5. I/O Signal Control and Signal Functions

z PIO pattern = 5: Solenoid valve mode 2 [3-point type]

Category Signal

name

Signal

abbreviation

Function overview

Rear end move
command

ST0

The actuator will move toward the rear end while this signal
remains at ON level.

Front end move
command

ST1

The actuator will move toward the front end while this signal
remains at ON level.

Intermediate point
move command

ST2

The actuator will move toward the intermediate point while this
signal remains at ON level.

Brake release

BKRL

This signal is used on an actuator equipped with a brake to
forcibly release the brake.

Operating mode

RMDO

This signal switches the operating mode between AUTO and
MANU.

Alarm reset

RES

An alarm is reset at a rise edge of this signal.

Input

Servo ON

SON

The servo remains ON while this signal is ON.
The servo remains OFF while this signal is OFF.

Rear end detected

LS0

This signal will remain ON while the rear end is recognized.
(This signal is not output during push & hold operation.)

Front end detected

LS1

This signal will remain ON while the front end is recognized.
(This signal is not output during push & hold operation.)

Intermediate point
detected

LS2

This signal will remain ON while the intermediate point is
recognized. (This signal is not output during push & hold
operation.)

Zone ZONE1

This signal becomes effective after home return. It will turn ON
when the current actuator position enters the range set by the
parameters and remain ON until the actuator exits the range.

Position zone

PZONE

This signal becomes effective after a position movement
command is input. It will turn ON when the current actuator
position enters the range specified in the position table and
remain ON until the actuator exits the range.

Operating mode status RMDS

This signal will remain OFF during the AUTO mode, and ON
during the MANU mode.

Home return
completion

HEND

This signal is OFF immediately after the power is input, and
turns ON when home return has completed.

Ready SV

This signal is always output once the servo is turned ON and
the controller is ready to operate.

*Emergency stop

*EMGS

OFF: Emergency stop has been actuated

*Alarm *ALM

This signal remains ON in normal conditions of use and turns
OFF when an alarm generates.

Load output judgment
status

LOAD

This signal will turn ON when the command torque exceeds
the threshold while the actuator is inside the check range.
Note) Dedicated output signal for the PCON-CF

Output

Torque level status

TRQS

This signal will turn ON when the motor current reaches the
threshold.
Note) Dedicated output signal for the PCON-CF