31

4. W

iring

z Connecting the teaching pendant to a SIO converter

Configure the contact circuit for the EMG switch on the teaching pendant using EMG1/EMG2 on the
power/emergency-stop terminal block on the SIO converter.
(S1/S2 on the controller’s terminal block are not used.)

EMG2 EMG1

CR

ON

OFF

MPI

MPO

24V

EMG-

0V

MPI

MPO

24V

EMG-

0V

MPI

MPO

24V

EMG-

0V

CR

EMG signal

Teaching pendant

24V

0V

[Controller 1]

[Controller 2]

[Controller 3]

SIO converter