IAI America PCON-CF User Manual
Page 157
![background image](/manuals/350314/157/background.png)
139
8. Parameter Settings
If the actuator is moved in the order to positions 1
Ж 2 Ж 3 Ж 4, the actuator will operate differently depending
on whether or not shortcut is selected, as explained below.
When shortcut is not selected
When shortcut is selected
z Absolute unit (No.83 ETYP)
Parameter No. 83 sets whether or not an optional simple absolute unit is used.
Setting
Not used
0
Used
1
z Current-limiting value at standstill after missing work part in push & hold operation (No. 91 PSFC)
This parameter defines the current-limiting value when the actuator is at standstill after missing the work part in
push & hold operation.
Parameter No. 91
Description
0
Current-limiting value at standstill
(An appropriate value has been set according to the characteristics of the
applicable actuator.)
1
Current-limiting value during push & hold operation
Point No. 1
Point No. 2
Point No. 3
Point No. 3
Point No. 2
Point No. 4
Point No. 4
Point No. 1
Point No. 1
Point No. 2
Point No. 3
Point No. 3
Point No. 2
Point No. 4
Point No. 4
Point No. 1