8. Parameter Settings

If the actuator is moved in the order to positions 1

Ж 2 Ж 3 Ж 4, the actuator will operate differently depending

on whether or not shortcut is selected, as explained below.

When shortcut is not selected

When shortcut is selected

z Absolute unit (No.83 ETYP)

Parameter No. 83 sets whether or not an optional simple absolute unit is used.

Setting

Not used

0

Used

1

z Current-limiting value at standstill after missing work part in push & hold operation (No. 91 PSFC)

This parameter defines the current-limiting value when the actuator is at standstill after missing the work part in
push & hold operation.

Parameter No. 91

Description

0

Current-limiting value at standstill

(An appropriate value has been set according to the characteristics of the

applicable actuator.)

1

Current-limiting value during push & hold operation

Point No. 1

Point No. 2

Point No. 3

Point No. 3

Point No. 2

Point No. 4

Point No. 4

Point No. 1

Point No. 1

Point No. 2

Point No. 3

Point No. 3

Point No. 2

Point No. 4

Point No. 4

Point No. 1