IAI America PCON-CF User Manual
Page 209
191
* Appendix
Appendix
Note
Use the table below as reference on the maximum limit number of push-motion operations when an actuator of each lead type is
operated with the maximum push force and push-motion travel of 1 mm.
Lead (type)
2.5
5
10
Number of push-
motion operations
1.4 million times
25 million times
157.6 million times
* The maximum limit number of push-motion operations varies depending on operating conditions such as impact and vibration.
The figures on the left assume that there is no shock or vibration.
RA10C type
Push force (N)
Current-limiting value (ratio, %)