Use the table below as reference on the maximum limit number of push-motion operations when an actuator of each lead type is
operated with the maximum push force and push-motion travel of 1 mm.

Lead (type)

2.5

5

10

Number of push-
motion operations

1.4 million times

25 million times

157.6 million times

* The maximum limit number of push-motion operations varies depending on operating conditions such as impact and vibration.