6SHFL¿FDWLRQV

2.

Specifications

2.1

Basic Specifications

Specification item

PCON-C

(Internal Drive-Power Cutoff

Relay Type)

PCON-CG

(External Drive-Power Cutoff

Relay Type)

PCON-CF

(Internal Drive-Power Cutoff

Relay Type)

Number of controlled axes

1 axis/unit

Supply voltage

24 VDC

r 10%

Actuator

Rated

Max. *2

Rated

Max. *2

Rated

Max. *3

20, 28P motor

0.4 A

0.4 A

35, 42, 56P motor

1.2 A

2.0 A

1.2 A

2.0 A

Power-source
capacity

86P motor

4.2 A

6.0 A

Heat output

9.6 W

9.6 W

26.4 W

Control method

Weak field-magnet vector control

Encoder resolution

Incremental specification 800 Puls/rev

Positioning command

Number of positioning points: 64 points (standard) to 512 points (maximum)
* The number of positioning points varies depending on the selected PIO

pattern.

Backup memory

Position data and parameters are saved in nonvolatile memory.
Serial EEPROM can be rewritten approx. 100,000 times.

PIO interface

24-VDC I/O

LED indicators

SV (green) --- Servo on, ALM (red) --- Alarm present

Serial communication

RS485, 1 channel (conforming to the Modbus protocol)

Electromagnetic-brake forced
release function

NOM/BK RLS switch (front panel)

Actuator cable: 20 m or less

Cable length

I/O flat cable: 5 m or less

Isolation strength

500 VDC, 10 M

:

Surrounding air
temperature

0 to 40

qC

Surrounding
humidity

85%RH or less (non-condensing)

Surrounding
environment

Refer to 3.1 Installation Environment

Storage
temperature

-10 to 65

qC

Storage humidity 90%RH or less (non-condensing)

Environment

Vibration
resistance

10 to 57 Hz in XYZ directions / Pulsating amplitude: 0.035 mm (continuous),
0.075 mm (intermittent)
57 to 150 Hz in XYZ directions: 4.9 m/s

2

(continuous), 9.8 m/s

2

Protection class

IP20

Cooling method

Natural air cooling

Forced air cooling

Weight

300 g or less

300 g or less

320 g or less

External dimensions

35 W x 175.5 H x 68.1 D mm

For the +24-V DC power supply,
select a unit of the “peak load
accommodation” specification or
having a sufficient allowance with
respect to the peak load. In
particular, exercise caution when
your system has a remote sensing
function.

*1 Rush current of around 5 to 12 times the rated current flows for approx. 1 to 2 msec

after the power is turned on. Take note that the value of rush current varies
according to the impedance of the power-supply line.

*2 Excitation detection operation is performed after the power is turned on. The

maximum current flows during this operation (normally for 100 msec).
Note, however, that approx. 6.0 A of current flows (for approx. 1 to 2 msec) if the
motor drive source is cut off and then turned on again.

*3 Excitation detection operation is performed after the power is turned on. The

maximum current flows during this operation (normally for 100 msec).

Note, however, that approx. 10.0 A of current flows (for approx. 1 to 2 msec) if the
motor drive source is cut off and then turned on again.

Caution: Position data, parameters, etc., are written to the EEPROM. Take note

that the EEPROM can be rewritten for up to approx. 100,000 times.