3 ethernet/ip interface – IAI America PCON-CFA User Manual

Page 97

background image

3. SCON-CA/CF

A

89

3.3

EtherNet/IP Interface

3.3.1

Names of the Parts

The names of each section related to EtherNet/IP are described as follows.

3.3.2

Monitor LED Indications

The slave condition (each controller), as well as network condition, can be checked using the two LEDs, MS

and NS, provided on the front panel of the controller.

The description of each is explained in the following table.

Name

Display color

Explanation

OFF

The power is turned off or IP address is not yet set.

GN㧔Illuminating㧕

Connection has been established and proper communication is in

progress.

GN (Flashing)

The system is online but connection is not yet established.

Communication is stopped (the network is normal). Check the status

of the master unit.

RED (Illuminating)

A communication error is present.

Communication cannot be

established because an error,

such as duplicate IP addresses,

has been detected.

NS

RED (Flashing)

A communication error is present.

(A communication timeout has

been detected.)

Check the IP address setting,

wiring condition of the

communication line, power supply

for the hub, noise measures, etc.

OFF

The power is turned off.

GN㧔Illuminating)

Operation is normal.

The system is in the scanner (master) control mode.

GN (Flashing)

Connection is not yet established with the scanner (master).

Check the setting of configuration information.

Check if the scanner (master) is idle.

RED (Illuminating)

A hardware error is present.

The board must be replaced. Please contact IAI.

NS

RED (Flashing)

A configuration error, invalid setting or other minor error is present.

The problem can be resolved by, for example, setting the problem

item or items again.

SV/ALM Status indicator LEDs

֥

Status LEDs

EtherNet/IP port

NS
MS