2.

ACON-C/CG, PCON-C/CG

69

(30) Stop Mode Selection (ASO1, ASO0) PLC Output Signal

Select the stop mode for the duration before the movement to the next position after a positioning is

completed.

If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power

consumption.

Refer to the operation manual for the controller for more information.

ASO1 ASO0

Functions

Reference

OFF

OFF

Disabled

(Set in delivery)

OFF

ON

Automatic Servo OFF Method

Parameter No. 36 is valid for T

ON

OFF

Automatic Servo OFF Method

Parameter No. 37 is valid for T

ON

ON

Automatic Servo OFF Method

Parameter No. 38 is valid for T

T :

T

Movement

Command

Actuator

Moving

Target Position

Servo

Condition

In automatic servo OFF duration

(Green LED blinks)

Servo ON

Condition

Waiting time (sec) before servo is

turned OFF after the positioning is completed

.