background image

4. SCON-CA

169

x

PLC output o SCON-CA input side (* “n” indicates the byte address of each axis.)

DO on the SCON-CA side and output data register

Position/Simplified

direct value mode 2

Half direct value

mode 2

Remote I/O mode 3

Half direct value

mode 3

PLC input

area

(bytes)

Number of occupied

bytes: 8

Number of occupied

bytes: 16

Number of occupied

bytes: 12

Number of occupied

bytes: 16

n+0, n+1

Port No.0 to 15

n+2, n+3

Target position

Target position

Target position

n+4, n+5

Specified position

number

n+6, n+7

Control signal

Positioning band

Positioning band

n+8, n+9

Speed

Speed

n+10, n+11

Acceleration/

Deceleration

Occupied area

Acceleration/

Deceleration

n+12, n+13

Pressing

current-limiting

value

Pressing

current-limiting

value

n+14, n+15

Control signal

Control signal

n+16, n+17
n+18, n+19
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
n+28, n+29
n+30, n+31

(Note) The Occupied area shows the area to be occupied with the operation mode setting.

Therefore, this area cannot be used for any other purpose. Also, exercise caution to avoid node address

duplication.