beautypg.com

7 i/o signal timings – IAI America PCON-CFA User Manual

Page 151

background image

3. SCON-CA/CF

A

143

PLC sequence program

Control signal

Status signal

PCON

Control signal

Status signal

Master station o Slave

transmission delay time (Yt)

Slave o Master station

Transmission delay time (Xt)

Command processing time

3.7

I/O Signal Timings

When any of the control signal is turned ON to perform the operation of the robot cylinder using the PLC's

sequence program, the response (status) is returned to the PLC. The maximum response time is expressed

using the following formula.

Maximum response time (msec)䋽Yt+Xt+3+ command processing time (operation time, etc.)

Yt: Master stationoslave transmission delay time

Xt: Slaveomaster station transmission delay time

Master Station o For the master station o slave transmission delay (Yt) and slave omaster station

transmission delay (Xt), refer to the operation manuals for the EtherNet/IP master unit

and PLC installed in the master unit.

Filed network transmission delay

time

This manual is related to the following products: